When you ask for a valve quotation, the first things any supplier will ask are the size, the pressure and the flange standard. The pressure part is where most confusion happens, because valves are marked PN10, PN16, Class 150, Class 300 and so on, and these labels come from two different systems. In short, PN ratings are metric (European) and Class ratings are American (ASME). They are not the same, they are not interchangeable, and in both systems the pressure a valve can safely hold goes down as temperature goes up. This guide explains all of it in simple terms. It comes from MD Valves, a Valve Manufacturer in India that checks rating and flange details on every order.
What A Pressure Rating Really Means
A pressure rating is the highest pressure a valve body is allowed to carry safely, at a stated temperature. It is not the same as the pressure in your pipe on a normal day. Your line has a working pressure (what it normally runs at), a design pressure (the highest pressure the system is designed for, with margin) and sometimes surge pressure (short spikes when a pump trips or a valve closes quickly). The valve rating must be higher than all of these. Factories also pressure-test each valve above its rating to prove it, which is called the test pressure.
In India you will also hear pressure in kg/cm². As a rough conversion, 1 bar is about 1.02 kg/cm², so 16 bar is roughly 16.3 kg/cm².
PN Ratings: The Metric System
PN stands for Pression Nominale, which means nominal pressure. The number after PN is a label that is roughly the pressure in bar at normal ambient temperature. So PN10 is about 10 bar and PN16 is about 16 bar. PN25 and PN40 are the higher steps. PN ratings go with metric flange standards such as EN 1092-1, and sizes are written as DN (diameter in millimetres). PN10 and PN16 are the everyday ratings for water supply, HVAC and general plant utility lines. Many wafer type butterfly valves are made with dual drilling so the same valve fits both PN10 and PN16 flanges.
Class Ratings: The American System
Class 150, Class 300, Class 600 and so on follow the ASME standards (B16.34 for valves and B16.5 for flanges), and sizes are in inches (NPS). Here is the part people miss: a Class number is not a direct pressure figure. It names a family of pressure and temperature limits, and the actual pressure you can use depends on the body material and the temperature. As a rough guide, a carbon steel valve is rated for about 19.6 bar at ambient temperature in Class 150 and about 51 bar in Class 300. In metric terms people often say Class 150 is close to PN20 and Class 300 is close to PN50, but the flanges still differ.
Why Temperature Changes The Allowed Pressure
Metal becomes weaker as it gets hotter, so a valve that holds 19.6 bar at room temperature cannot hold the same pressure at 300°C. The table below shows approximate values for carbon steel (ASTM A216 WCB). Treat them as a guide and always confirm against ASME B16.34 or the manufacturer's datasheet for your exact material, because stainless steel, alloy steel and cast iron have their own tables.
Temperature | Class 150 (bar) | Class 300 (bar) |
| 38°C (ambient) | 19.6 | 51.1 |
| 100°C | 17.7 | 46.6 |
| 200°C | 13.8 | 43.8 |
| 300°C | 10.2 | 39.8 |
| 400°C | 6.5 | 34.7 |
Seats and seals also have their own temperature limits. EPDM, NBR, PTFE and metal seats all fail at different temperatures, so the real limit of a valve is the lowest of the body, seat and seal ratings.
Why PN and Class Cannot Be Swapped
They may look alike, but the flanges are built to different dimensions. The bolt circle diameter, the number of bolts and the flange thickness are usually different. In a few sizes they look close enough to tempt shortcuts, but forcing a mismatch causes leaks and damaged gaskets. So never assume PN16 equals Class 150. One more practical warning: do not bolt a flat-face cast iron flange to a raised-face steel flange, because the cast iron can crack when the bolts are tightened.
How Valves Are Tested
Under common standards such as API 598 and EN 12266, a valve gets a shell test at about 1.5 times its rated pressure to prove the body is strong, and a seat test at about 1.1 times to prove it seals. Ask your supplier for the test report with your order. It is the simplest proof that the rating is real.
Do Not Forget Pressure Surges
When flowing water is stopped suddenly, the energy turns into a pressure spike called water hammer. A simple estimate is: pressure rise = density of water x speed of the pressure wave x change in flow velocity. In a steel water pipe the wave speed is about 1,200 metres per second, so stopping a flow of 1 metre per second instantly can add around 12 bar. That means a PN16 valve on a line running at 8 bar can be overstressed by a fast-closing valve or a pump trip. Slow valve closing, surge vessels and non-slam check valves all reduce the risk.
How To Choose The Right Rating
Start with the highest working pressure including surge, then note the highest operating temperature. Next, find out which flange standard and size your pipeline uses (PN or ASME, DN or inches). Choose the body material and read its pressure and temperature limit, add the safety margin your design code or consultant requires, and finally check that the seat and seal also suit the temperature.
Here are two quick examples. For steam at 12 bar and 200°C in a carbon steel line, Class 150 allows only about 13.8 bar at that temperature, which leaves very little margin, so Class 300 is the safer choice. For treated water at 8 bar and 40°C, a PN16 butterfly valve gives comfortable margin.
Mistakes To Avoid
The usual mistakes are choosing a rating by pipe size alone, ignoring temperature, mixing PN and ASME flanges, forgetting surge pressure, and picking the lowest rating to cut cost. If you plan to automate the valve, the actuator must be sized for the torque at full pressure. For slurry lines, where knife gate valves are normally used at low to moderate pressure, see Knife Gate vs Butterfly vs Ball Valve.
Let MD Valves Check Your Rating
Send MD Valves your pressure, temperature, media, size and flange standard, and our engineers will confirm the right rating, body material and seat before you order. MD Valves is an Ahmedabad-based Valve Manufacturer in India supplying manual, pneumatic and electric valves, with quotations within 24 hours.
- Talk to an expert: +91 9664718881 or +91 91067 77653
- Email: info@mdvalves.in
- Request a quote | Download our catalogue
Frequently Asked Questions
What does PN16 mean?
PN16 is a metric designation meaning the valve is designed for about 16 bar at ambient temperature.
Is Class 150 the same as PN16?
No. They belong to different standards and have different flange dimensions. Class 150 is closer to PN20 in pressure.
How does temperature affect pressure rating?
Allowed pressure falls as temperature rises. A Class 150 carbon steel valve drops from about 19.6 bar at ambient to about 13.8 bar at 200°C.
Which rating should I choose?
Choose from maximum working pressure including surge, operating temperature, body material and your flange standard.
What is the test pressure of a valve?
Shell tests are commonly done at about 1.5 times the rating and seat tests at about 1.1 times.